Inversor solar MUST EP3300 TLV do catálogo 2026
MUST EnergySolução durável
Inversores de 110 VMUST

EP3300 TLV

Inversor solar MUST EP3300 TLV da linha 2026, com potência de 1–6 kW e saída CA de 110/220 V. Consulte a ficha completa para comparar modelos, proteções, comunicação, dados elétricos e dimensões.

Potência1–6 kW
Saída CA110/220 V
TopologiaSplit phase
ComunicaçãoWi-Fi e BMS

Principais parâmetros da série

PARÂMETROS PRINCIPAIS
MODELOEP33-1012
TLV
EP33-1024
TLV
EP33-1512
TLV
EP33-1524
TLV
EP33-2012
TLV
EP33-2024
TLV
EP33-3024
TLV
EP33-3048
TLV
EP33-4024
TLV
EP33-4048
TLV
EP33-5048
TLV
EP33-6048
TLV
SAÍDA DO INVERSOR
Rated power1KW1.5KW2KW3KW4KW5KW6KW
Surge rating3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Capable of starting electric motor1P1P1.5P1.5P2P3P
Power factor1
Wave formPure sine wave / Same as input wave form (bypass mode)
Output voltage RMS100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
Output frequency50Hz or 60Hz (±0.3Hz) (can be set)
Overload protectionBreaker + software protection
Output short circuitBreaker + software protection
Inverter efficiency (peak)>85%
Overload100% < Load < 110% (alarm 5min then stop output and fault code 07)
110% < Load < 125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
BATERIA
Battery voltage12VDC / 24VDC24VDC / 48VDC48VDC
Minimum start voltage(10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm(10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm(12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover(12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Save modeLoad ≤50±20W(120V)/100±20W(220V)
AC INPUT MODE
Input waveformPure sine wave
Nominal input voltage200Vac / 220Vac / 240Vac
Max input voltage270Vac MAX
Input frequency50Hz / 60Hz (auto sensing)
Efficiency (AC mode)>95% (load, full battery)
Transfer time AC to DC15ms(max)
Transfer time DC to AC15ms(max)
OUTROS PARÂMETROS
MODELOEP33-1012
TLV
EP33-1024
TLV
EP33-1512
TLV
EP33-1524
TLV
EP33-2012
TLV
EP33-2024
TLV
EP33-3024
TLV
EP33-3048
TLV
EP33-4024
TLV
EP33-4048
TLV
EP33-5048
TLV
EP33-6048
TLV
CHARGE MODE
Boost voltage14.1V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
Float voltage13.5V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
12V30A45A60A////
24V20A25A30A40A60A//
48V///20A30A35A40A
Min charge current 10A. Change by every 5A
ESPECIFICAÇÕES MECÂNICAS
Machine Dimension (W*H*D)(mm)359.2*443*188361.8*543.5*188.5
Package Dimension (W*H*D)(mm)598*308*457698*308*407
N.W(kg)/
G.W(kg)/
Standard Warranty1 year (standard), 2 years optional (IP20)
CERTIFICAÇÕES E NORMAS
CE-LVD: EN 62109-1:2010;EN 62109-2:2011; CE-EMC:EN IEC 61000-6-1 EN IEC 61000-6-3

O preço depende do modelo e da configuração.

EP3300 TLV | MUST Brasil