Inversor solar MUST EP3000 LV do catálogo 2026
MUST EnergySolução durável
Inversores de 110 VMUST

EP3000 LV

Inversor solar MUST EP3000 LV da linha 2026, com potência de 1–6 kW e saída CA de 110/115/120 V. Consulte a ficha completa para comparar modelos, proteções, comunicação, dados elétricos e dimensões.

Potência1–6 kW
Saída CA110/115/120 V
Bateria12/24/48 V CC
ComunicaçãoWi-Fi e BAT-CAN

Principais parâmetros da série

PARÂMETROS PRINCIPAIS
MODELOEP30-1012
LV
EP30-1024
LV
EP30-1512
LV
EP30-1524
LV
EP30-2012
LV
EP30-2024
LV
EP30-3024
LV
EP30-3048
LV
EP30-4024
LV
EP30-4048
LV
EP30-5048
LV
EP30-6048
LV
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC24VDC48VDC24VDC48VDC48VDC48VDC
SAÍDA DO INVERSOR
Reted Power1.0KW1.5KW2KW3KW4KW5KW6KW
Surge Rating3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Capable Of Starting Electric Motor1HP2HP3HP
WaveformPure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS110V/115V/120VAC ±10% (RMS)
Output Frequency50Hz / 60Hz±0.3 Hz
Inverter Efficiency(Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
Overload100% < Load < 110% (alarm 5min then stop output and fault code 07)
110% < Load < 125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
ENTRADA CA
Voltage120VAC
Selectable Voltage Range75~135VAC(For Personal Computers)
Frequency Range50Hz/60Hz (Auto sensing) 40~80Hz
BATERIA
Minimum Start Voltage(10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm(10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm(12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage recover(12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Energy saving modeLoad ≤50±20W(120V)
CARREGADOR
Output VoltageDepends on battery type
Charger AC Input Breaker Rating1K/30A3K/40A4-6KW/63A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current30A20A45A25A60A30A40A20A60A30A35A40A
BYPASS E PROTEÇÕES
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
AC Input Breaker30A40A50A / 63A
OUTROS PARÂMETROS
MODELOEP30-1012
LV
EP30-1024
LV
EP30-1512
LV
EP30-1524
LV
EP30-2012
LV
EP30-2024
LV
EP30-3024
LV
EP30-3048
LV
EP30-4024
LV
EP30-4048
LV
EP30-5048
LV
EP30-6048
LV
ESPECIFICAÇÕES MECÂNICAS
MountingWall Mount
Machine Dimension (W*H*D)(mm)303*493*200305*531*202
Package Dimension (W*H*D)(mm)615*319*400686*319*400
N.W(kg)/
G.W(kg)/
OUTROS
Operation Temperature Range0°C to 40°C
Storage Temperature-15°C to 60°C
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty2 year

O preço depende do modelo e da configuração.

EP3000 LV | MUST Brasil